Programming Manual 2 - 641
Program
51
Description
Use Program 51-01 : NetLink System Property Setting to define the
parameters of the NetLink feature.
Each system must be set with its own information.
When the NetLink System ID is changed (Item 01), the system must be reset.
Program 51 : NetLink Service
51-01 : NetLink System Property Setting
Level:
IN
Input Data
Item
No.
Item Input Data Default
01
NetLink System ID
This is the ID of each NetLink system.
Setting should insure that no overlap
occurs between nodes.
0~50
(0 = No operation)
0
02
Primary Candidate Order
When the Primary system is turned off
or disconnect from network, this value
is used to select a new Primary
system. Smaller number is higher
priority.
If this value is the same number, the
System ID (PRG 51-01-01) is referred,
and the system which has the smaller
number is selected as Primary system.
1~50
30
03
Secondary System Flag
0: NetLink is dynamically established
based on Node List in PRG 51-03-01.
Primary System will be selected in the
order which the system wakes up.
1: The system connects with Top
Priority Primary System.
If Top Priority Primary System was not
found, the system searches Primary
System like this setting is 0.
0 = Disable
1 = Enable
0