EasyManua.ls Logo

NEC Univerge SV8100 - 34-11: E1 Trunk Basic Setup (OT)

NEC Univerge SV8100
986 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 465
Description
Use Program 34-11: E1 Trunk Basic Setup to define the basic setting of each E1
Trunk.
Program 34 : Tie Line Setup
34-11: E1 Trunk Basic Setup (OT)
Level:
IN
Input Data
Trunk Port Number 1~200
Item
No.
Name Input Data Default
01
E1 Trunk Type
Use this option to specify the
E1Signal type(0-8). Set this option
for compatibility with the
connected telco.
0 = Standard Trunk
1 = Argentine Pulsed Clear Back Trunk
2 = Argentine Pulsed Answer Trunk
3 = Brazil With seizure acknowledge
Trunk
4 = Brazil Without seizure acknowledge
Trunk
5 = Brazil E&M Signal A(Idle=0) Trunk
6 = Brazil E&M Signal A(Idle=1) Trunk
7 = Brazil E&M Signal B(Idle=0) Trunk
8 = Brazil Code for collect call blocking
Trunk
0
02
MFC Dialing Type
Use this option to specify the MFC
Dialing Type. The following table
shows the available MFC Dialing
Type choices, By default, this
option is 0 (MFC Dialing not used).
0 = MFC Dialing not used
1 = NEC Standard
2 = Argentina
3 = Brazil
4 = Chile
5 = Colombia
6 = Mexico
7= Venezuela
0
03
MFC Group B
Use this option to enable(1) or
disable(0) the MFC Dialing Group
B supervisory signaling. Since not
all central offices provide Group B
signaling, set this option for
compatibility with the connected
telco. By default, this option is
Disable(0).
0 = Disable
1 = Enable
0