Issue 10.1 UNIVERGE SV8100
2 - 868 Program 90 : Maintenance Program
Description
Use Program 90-10: System Alarm Setup to assign a status to system alarms. You
can designate an alarm as Major or Minor. This program also assigns whether or not
the alarm information is reported to the pre-defined destination.
Program 90 : Maintenance Program
90-10: System Alarm Setup
Level:
IN
Input Data
Alarm Number 001~100
Item No. Item Input Data
01
Alarm Type
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
02
Report
0 = Not Report (No autodial)
1 = Report (autodial)
Table 2-20 Description of Alarm
Alarm
No.
Type Report Name Content of Alarm Cause Action Recovery
Alarm
Status
1 2 0 PKG Initialize
Error.
1. The PKG failed to
initialize.
2. The PKG did not start
normally.
1. PKG not inserted
firmly.
2. PKG was
removed, but not
reinserted firmly.
3. Old PKG data
still reported due to
no initialization.
1. Insert PKG firmly.
2. Insert PKG firmly.
3. Delete slot
information in
PRG 90-05 and insert
the PKG again.
During
initialization,
the PKG is
recognized.
ERR
REC
2 2 0 PKG Mount-
ing Error
The unit did not step on a
regular procedure and it
was pulled out. Or, it is not
normally inserted.
1.The package is
not completely
inserted.
2.The package is
out of order.
1.Please insert the
package firmly.
2.Please try again after
initializing the system
data once when LED
doesn't blink normally.
3.Exchange packages.
When unit is
reconfirmed,
the error is
recovered.
ERR
REC

Table of Contents