UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 41
Description
Use Program 10-23 : SIP System Interconnection Setup to determine if the system
is interconnected and define the IP address of another system, call control port
number and alias address for SV8100 system interconnection.
Conditions
None
Feature Cross Reference
None
Program 10 : System Configuration Setup
10-23 : SIP System Interconnection Setup
Level:
SA
Input Data
System Number
001~1000
Input Data
Item No. Item Input Data Default
01
System
Interconnection
0 = No (Disable)
1 = Yes (Enable)
0
02
IP Address
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
0.0.0.0
03
Call Control Port
1~65535
1720
04
Dial Number
Up to 12 digits (0~9)
Not Set