Issue 10.1 UNIVERGE SV8100
2 - 350 Program 22 : Incoming Call Setup
Description
Use Program 22-07: DIL Assignment to assign the destination extension or
Department Calling Group for each DIL Incoming trunk. A DIL rings an extension
directly, without any other Access Map or Ring Group programming. If an extension
has a line key, the DIL rings the line key. Use Program 22-02 to designate a trunk as a
DIL. You can make eight DIL assignments, one for each Night Service mode.
Conditions
Program 22-02 must be set to four for the trunk.
Feature Cross Reference
Direct Inward Line (DIL)
Program 22 : Incoming Call Setup
22-07: DIL Assignment
Level:
IN
Input Data
Trunk Port Number 001~200
Day/Night Mode 1~8
Item
No.
Item Input Data Default
01 Destination Number Extension Number or Department Group
Number (maximum eight digits)
No Setting