Description
Use Program 12-02: Automatic Night Service Patterns to define the daily pattern
of the Automatic Mode Switching. Each Mode Group has 10 patterns. These patterns
are used in Programs 12-03 & 12-04. The daily pattern consists of 20 timer Settings.
Example:
Time Pattern 1
To make the above schedule, it is necessary to set the data as follows:
Program 12 : Night Mode Setup
12-02: Automatic Night Service Patterns
Level:
SA
Input Data
Night Mode Service Group Number 01~32
Time Pattern Number 01~10
Set Time Number 01~20
Item Description Input Data
01
Start Time
0000~2359
02
End Time
0000~2359
03
Operation Mode
1~8
0:00 9:00 12:00 13:00 17:00 18:00 22:00 0:00
Mode 3 Mode 1 Mode 4 Mode 1 Mode 4 Mode 2 Mode 3
(midnight) (day) (rest) (day) (rest) (night) (midnight)
Time setting 01: 00:00 to 09:00 Mode 3 (midnight)
Time setting 02: 09:00 to 12:00 Mode 1 (day)
Time setting 03: 12:00 to 13:00 Mode 4 (rest)
Time setting 04: 13:00 to 17:00 Mode 1 (day)
Time setting 05: 17:00 to 18:00 Mode 4 (rest)
Time setting 06: 18:00 to 22:00 Mode 2 (night)
Time setting 07: 22:00 to 00:00 Mode 3 (midnight)