Description
Use Program 10-32: PRI Networking Maximum PRI Channel Setup to assign the
number of B-channels to be used for each ISDN blade. This allows for fractional PRIs
when used with multiple site networking.
If this program is limited to less than “30” on one side of the network, then it also limits
both inbound and outbound network calls. For example, when you select 10 channels
then only channels 1 to 10 will be available. If a call is attempted on channels 11 to 30
the caller will receive busy tone. This also applies on the other side of the network as
well.
The setting is for each slot within the SV8100; ensure that you select the correct slot
before making any changes.
This program will not affect a PRI card set as Trunk or Station mode.
Conditions
None
Feature Cross Reference
Networking - AspireNet (OT)
Program 10 : System Configuration Setup
10-32: Networking Maximum PRI Channel Setup (OT)
Level:
IN
Input Data
Slot Number 1-24
Item
No.
Item Input Data Default
01
Maximum Channels
Set the maximum number of channels which can be used with
PRI NetLink.
1 - 30
30