EasyManua.ls Logo

NEC Univerge SV8100 - 81-08: T1 Trunk Timer Setup

NEC Univerge SV8100
986 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 709
Description
Use Program 81-08: T1 Trunk Timer Setup to define the basic timer setting of each
T1 Trunk type.
Program 81 : Basic Hardware Setup for Trunk
81-08: T1 Trunk Timer Setup
Level:
IN
Item Name Input Data Default
01
Answer Signal Detection Time
(Loop)
1~250
(4ms ~ 1000ms)
15
60ms
02
Answer Signal Detection Time
(Ground)
1~250
(4ms ~ 1000ms)
15
60ms
03
Answer Signal Detection Time
(DID)
1~250
(4ms ~ 1000ms)
15
60ms
04
Answer Signal Detection Time
(E&M)
1~250
(4ms ~ 1000ms)
15
60ms
05
Answer Signal Detection Time
(OPX)
1~250
(4ms ~ 1000ms)
15
60ms
06
Clear Signal Detection Time
(Loop)
1~255
(100ms ~ 25500ms)
6
600ms
07
Clear Signal Detection Time
(Ground)
1~255
(100ms ~ 25500ms)
6
600ms
08
Clear Signal Detection Time
(DID)
1~255
(100ms ~ 25500ms)
6
600ms
09
Clear Signal Detection Time
(E&M)
1~255
(100ms ~ 25500ms)
6
600ms
10
Clear Signal Detection Time
(OPX)
1~255
(100ms ~ 25500ms)
6
600ms
11
Ringing Signal Detection Time
(Loop)
1~250
(8ms ~ 2000ms)
10
80ms
12
Ringing Signal Detection Time
(Ground)
1~250
(8ms ~ 2000ms)
10
80ms
13
Ringing Signal Detection Time
(DID)
1~250
(8ms ~ 2000ms)
10
80ms