EasyManua.ls Logo

NEC Univerge SV8100 - Page 746

NEC Univerge SV8100
986 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 10.1 UNIVERGE SV8100
2 - 710 Program 81 : Basic Hardware Setup for Trunk
14
Ringing Signal Detection Time
(E&M)
1~250
(8ms ~ 2000ms)
10
80ms
15
Ringing Signal Detection Time
(OPX)
1~250
(8ms ~ 2000ms)
10
80ms
16
Ringing Signal Stop Detection
Time (Loop)
1~255
(100ms ~ 25500ms)
50
5000ms
17
Ringing Signal Stop Detection
Time (Ground)
1~255
(100ms ~ 25500ms)
50
5000ms
18
Ringing Signal Stop Detection
Time (DID)
1~255
(100ms ~ 25500ms)
50
5000ms
19
Ringing Signal Stop Detection
Time (E&M)
1~255
(100ms ~ 25500ms)
50
5000ms
20
Ringing Signal Stop Detection
Time (OPX)
1~255
(100ms ~ 25500ms)
50
5000ms
21
Loop Current Detection Time
(Loop)
1~250
(4ms ~ 1000ms)
40
160ms
22
Loop Current Detection Time
(Ground)
1~250
(4ms ~ 1000ms)
40
160ms
23
Loop Current Detection Time
(DID)
1~250
(4ms ~ 1000ms)
40
160ms
24
Loop Current Detection Time
(E&M)
1~250
(4ms ~ 1000ms)
40
160ms
25
Loop Current Detection Time
(OPX)
1~250
(4ms ~ 1000ms)
40
160ms
26
DP Break Send Time (ALL)
1~250
(4ms ~ 1000ms)
15
60ms
27
DP Make Send Time (ALL)
1~250
(4ms ~ 1000ms)
10
40ms
28
DP Inter Digit Send Time (ALL)
1~255
(100ms ~ 25500ms)
7
700ms
29
Hook Flash Send Time (Loop)
1~255
(100ms ~ 25500ms)
5
500ms
30
Hook Flash Send Time (Ground)
1~255
(100ms ~ 25500ms)
5
500ms
31
Hook Flash Send Time (DID)
1~255
(100ms ~ 25500ms)
5
500ms
32
Hook Flash Send Time (E&M)
1~255
(100ms ~ 25500ms)
5
500ms
Item Name Input Data Default