Issue 10.1 UNIVERGE SV8100
2 - 742 Program 82 : Basic Hardware Setup for Extension
Description
Use Program 82-04: LCA Initial Data Setup to set the basic data of the LCA.
Program 82 : Basic Hardware Setup for Extension
82-04: LCA Initial Data Setup
Level: Level:
IN (OT) MF (AU)
Input Data
Item No. Item Input Data Default
01
Companding Method Type
0 = u-law
1 = A-law
1
02
Ringing Frequency
0 = 25Hz
1 = 20Hz
2 = 16Hz
0 (25Hz)
03
Minimum Break Time
1~255 (5ms~1275ms)
2 (10ms)
04
Maximum Break Time
1~255 (5ms~1275ms)
20(100ms) (OT)
15(75ms) (AU)
05
Minimum Make Time
1~255 (5ms~1275ms)
2 (10ms)
06
Maximum Make Time
1~255 (5ms~1275ms)
20 (100ms) (OT)
15 (75ms) (AU)
07
Minimum Hook Flash Time
1~255 (5ms~1275ms)
21 (105ms) (OT)
17 (85ms) (AU)
08
Maximum Hook Flash Time
1~255 (5ms~1275ms)
200 (1000ms) (OT)
120 (600ms) (AU)
09
Minimum Ground Flash Time
1~255 (5ms~1275ms)
21 (105ms)
10
Minimum Off-Hook Time
1~255 (5ms~1275ms)
21 (105ms)
11
No Detection Time after Off-Hook
1~255 (5ms~1275ms)
60 (300ms)
12
No Detection Time after Pulse Dial
Detection
1~255 (5ms~1275ms)
70 (350ms)
13
Loop Disconnect Time, Reversal
Time
1~255 (10ms~2550ms)
60 (600ms)
14
Ring, Message Wait Period Time
1~255 (5ms~1275ms)
150 (750ms)