EasyManua.ls Logo

NEC Univerge SV8100 - 82-04: LCA Initial Data Setup

NEC Univerge SV8100
986 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 10.1 UNIVERGE SV8100
2 - 742 Program 82 : Basic Hardware Setup for Extension
Description
Use Program 82-04: LCA Initial Data Setup to set the basic data of the LCA.
Program 82 : Basic Hardware Setup for Extension
82-04: LCA Initial Data Setup
Level: Level:
IN (OT) MF (AU)
Input Data
Item No. Item Input Data Default
01
Companding Method Type
0 = u-law
1 = A-law
1
02
Ringing Frequency
0 = 25Hz
1 = 20Hz
2 = 16Hz
0 (25Hz)
03
Minimum Break Time
1~255 (5ms~1275ms)
2 (10ms)
04
Maximum Break Time
1~255 (5ms~1275ms)
20(100ms) (OT)
15(75ms) (AU)
05
Minimum Make Time
1~255 (5ms~1275ms)
2 (10ms)
06
Maximum Make Time
1~255 (5ms~1275ms)
20 (100ms) (OT)
15 (75ms) (AU)
07
Minimum Hook Flash Time
1~255 (5ms~1275ms)
21 (105ms) (OT)
17 (85ms) (AU)
08
Maximum Hook Flash Time
1~255 (5ms~1275ms)
200 (1000ms) (OT)
120 (600ms) (AU)
09
Minimum Ground Flash Time
1~255 (5ms~1275ms)
21 (105ms)
10
Minimum Off-Hook Time
1~255 (5ms~1275ms)
21 (105ms)
11
No Detection Time after Off-Hook
1~255 (5ms~1275ms)
60 (300ms)
12
No Detection Time after Pulse Dial
Detection
1~255 (5ms~1275ms)
70 (350ms)
13
Loop Disconnect Time, Reversal
Time
1~255 (10ms~2550ms)
60 (600ms)
14
Ring, Message Wait Period Time
1~255 (5ms~1275ms)
150 (750ms)

Table of Contents

Other manuals for NEC Univerge SV8100

Related product manuals