UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 745
Description
Use Program 82-06: ISDN BRI&PRI Layer3 (S-Point) Timer Setup to set the basic
timer for the layer 3 of ISDN BRI & PRI S-Point.
Program 82 : Basic Hardware Setup for Extension
82-06: ISDN BRI&PRI Layer3 (S-point) Timer Setup
Level:
IN
Input Data
Layer3 Timer Type No. 1~ 5
Input Data
Item No. Item Input Data Default
01
T301
0, 180~254(sec9
180(sec)
02
T302
1~254(sec)
10(sec)
03
T303
1~254(sec)
4(sec)
04
T304
0~254(sec)
20(sec)
05
T305
1~254(sec)
30(sec)
06
T306
0~254(sec)
30(sec)
07
T307
1~254(sec)
180(sec)
08
T308
1~254(sec)
4(sec)
09
T309
1~254(sec)
90(sec)
10
T310
0~180(sec)
30(sec)
11
T312
1~254(sec)
6(sec)
12
T313
1~254(sec)
4(sec)
13
T314
1~254(sec)
4(sec)
14
T316
(T317 + 1) ~254(sec)
120(sec)
15
T317
1~(T316-1)(sec)
60(sec)
16
T318
1~254(sec)
4(sec)
17
T319
1~254(sec)
4(sec)
18
T320
1~254(sec)
30(sec)