Issue 10.1 UNIVERGE SV8100
2 - 542 Program 44 : ARS/F-Route Setup
Description
Use Program 44-08: Time Schedule for ARS/F-Route to define the daily pattern of the
ARS/F-Route feature. ARS/F-Route has 10 time patterns. These patterns are used in
Program 44-09 and 44-10. The daily pattern consists of 20 time settings.
Default
All Schedule Patterns: 0:00 – 0:00, Mode 1
Example:
Pattern 1
Time Number 01: 00:00 – 08:00 Mode 3
Time Number 02: 08:00 – 18:00 Mode 1
Time Number 03: 18:00 – 22:00 Mode 2
Time Number 04: 22:00 – 00:00 Mode 3
Pattern 2
Time Number 01: 0:00 – 0:00 Mode 2
Program 44 : ARS/F-Route Setup
44-08: Time Schedule for ARS/F-Route
Level:
IN
Input Data
Schedule Pattern Number 01~10
Time Number 01~20
Item
No.
Item Start Time End Time Mode
01 Time Schedule for ARS/F-Route 0000~2359 0000~2359 1~8
0:00 8:00 18:00 22:00 0:00
Mode 3 Mode 1 Mode 2 Mode 3
0:00 0:00
Mode 2