Use Program 81-01: COT Initial Data Setup to define the various basic data
parameters for the COT Unit.
Program 81 : Basic Hardware Setup for Trunk
81-01 : COT Initial Data Setup
Level:
IN
Input Data
Item
No.
Item Input Data Default
01
PCM Encoding Method
Specification
0 = u-law
1 = A-law
1 (A-law)
02
Loop Current Detection Time
1~255
(8~2040ms)
75 (600ms)
03
Clear Signal (Open Loop)
Detection Time
This is the loop start trunk disconnect
recognition timer.
1~255
(8~2040ms)
37 (296ms)
04
Ringing Signal Detection Minimum
Time
1~255
(8~2040ms)
13 (104ms)
05
Single Ringing Detection Minimum
Time
0~255
(0,8~2040ms)
82 (656ms)
06
Double Ringing Detection
Minimum Off Time
0~255
(0,8~2040ms)
13 (104ms)
07
Double Ringing Detection
Maximum Off Time
0~255
(0,8~2040ms)
50 (400ms) (OT)
75 (600ms) (AU)
08
Ringing Signal not Detection
Minimum
1~255
(8~2040ms)
88 (704ms)
09
Time Ringing Signal Stop
Detection Time
1~255
(64~16320ms)
63 (4032ms) (OT)
38 (2432ms) (AU)
10
Continuous Ringing Minimum
Time
0~255
(0,8~2040ms)
38 (304ms) (OT)
25 (200ms) (AU)
11
Continuous Ringing Maximum
Time
0-255
(0,8~2040ms)
88 (704ms)
12
Caller ID Detection Time
0~255
(0~16320ms)
4 (0ms)