Issue 10.1 UNIVERGE SV8100
2 - 696 Program 81 : Basic Hardware Setup for Trunk
13
Grounding Time
1~255
(16~4080ms)
9 (144ms)
14
Hook Flash 1 Time
1~255
(16~4080ms)
50 (800ms) (OT)
6 (96ms) (AU)
15
Hook Flash 2 Time
1~255
(16~4080ms)
156 (2496ms)
16
Pause Time
1~255
(64~16320ms)
47 (3008ms)
17
PFT Idle Detection Time
1~255
(64~16320ms)
47 (3008ms)
18
Grounding Start Time
1~255
(8~2040ms)
6 (48ms)
19
Grounding Start Give Up Time
1~255
(64~16320ms)
47 (3008ms)
20
Loop Reverse Detect Minimum
Time
1~255
(8~2040ms)
13 (104ms)
21
Loop Reverse Detect Maximum
Time
1~255
(8~2040ms)
107 (856ms)
22
Loop Disconnect Detect Minimum
Time
When using dial pulse trunks this
timer is used to set the minimum
value for the system to detect the
disconnect pulse.
1~255
(8~2040ms)
63 (504ms)
23
Loop Disconnect Detect Maximum
Time
When using dial pulse trunks this
timer is used to set the maximum
value for the system to detect the
disconnect pulse.
1~255
(8~2040ms)
87 (696ms)
24
On Hook Normal Detect Time
1~255
(8~2040ms)
3 (24ms)
25
On Hook Reverse Detect Time
1~255
(8~2040ms)
2 (16ms)
26
On Hook Disconnect Detect Time
1~255
(16~4080ms)
188 (3008ms)
27
Dial Pulse Break Time (10pps)
1~255
(8~2040ms)
8 (64ms) (OT)
13 (104ms) (AU)
28
Dial Pulse Make Time (10pps)
1~255
(8~2040ms)
4 (32ms) (OT)
7 (56ms) (AU)
Input Data
Item
No.
Item Input Data Default