Programming Manual 2 - 667
Program
80
Description
Use Program 80-01: Service Tone Setup to define up to 64 Service Tones.
Each service tone is defined by the combination of 32 Basic Tones.
Program 80 : Basic Hardware Setup for System
80-01 : Service Tone Setup
Level:
IN
Input Data
Service Tone Number 01~64
Item No. Item Input Data
01
Repeat Count
0~255 (0 = until On-Hook)
Service Tone Number 01~64
Unit Number 1~8
Item No. Item Input Data
02
Basic Tone Number
0~33
(0 = No Tone)
(33 = Default Time Slot)
03
Duration Count
0~255 (0,100~25500ms)
04
Gain Level (dB)
0~63 (-15.5 ~ +15.5)