Programming Manual 2 - 763
Program
84
Description
Use Program 84-01 : H.323 Trunk Basic Information Setup to set the basic
information of the H.323 Trunk.
Program 84 : Hardware Setup for VoIP
84-01 : H.323 Trunk Basic Information Setup
Level:
IN
Input Data
Item
No.
Item Input Data Default
02
Number of G.711 audio frames
1~4
3
03
G.711 VAD mode
0 = Disable
1 = Enable
0
04
G.711 Type
0 = A-law
1 = u-law
0
05
Number of G.729 audio frames
1~6
1 = 10ms
2 = 20ms
3 = 30ms
4 = 40ms
5 = 50ms
6 = 60ms
3
06
G.729 VAD mode
0 = Disable
1 = Enable
0
07
G.729 Jitter Buffer( min)
0~270ms
30
08
G.729 Jitter Buffer (average)
0~270ms
60
09
G.729 Jitter Buffer (max)
0~270ms
120
11
Number of G.723 audio frames
1~2
1
12
G.723 VAD mode
0 = Disable
1 = Enable
0
15
Jitter Buffer Mode
1 = Fixed
2 = Self adjusting (silence period)
3 = Self adjusting
3