Issue 10.1 UNIVERGE SV8100
2 - 336 Program 21 : Outgoing Call Setup
Description
Use Program 21-21 : Toll Restriction for Trunks (Seized Trunk Basis Setting) to
define the toll restriction class to each trunk. The details of toll restriction are defined
by PRG 21-05 and 21-06.
This program is compared to Station Restriction Class. The higher class is applied.
Conditions
None
Feature Cross Reference
None
Program 21 : Outgoing Call Setup
21-21 : Toll Restriction for Trunks (Seized Trunk Basis Setting)
Level:
IN
Input Data
Trunk Port Number 001~200
Day/Night Mode 1~9 (9 = Power Failure mode)
Item
No.
Item Input Data Default
Related
Program
01
Restriction Class
Enter the Toll Restriction Class for the selected
trunk.
1~15
1 14-01-08
21-05