EasyManua.ls Logo

NEC Univerge SV8100 - Call Progress Tone Detector Setup

NEC Univerge SV8100
986 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 10.1 UNIVERGE SV8100
2 - 682 Program 80 : Basic Hardware Setup for System
Description
Use Program 80-04 : Call Progress Tone Detector Setup to define the various
levels and timers for the Call Progress Tone Detector.
Tone Detector Type:
1 = Dial Tone for Trunk
2 = Busy Tone for Trunk
3 = Ring Back Tone for Trunk
4 = Special Busy Tone for Trunk
5 = Special Ring Back Tone for Trunk
Program 80 : Basic Hardware Setup for System
80-04 : Call Progress Tone Detector Setup
Level:
IN
Input Data
Tone Detector Type Number 1 = Dial Tone for Trunk
2 = Busy Tone for Trunk
3 = Ring Back Tone for Trunk
4 = Special Busy Tone for Trunk
5 = Special Ring Back Tone for Trunk
Item No Item Input Data
01
Detection Level
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
02
Min. Detection Level
0~15
0 = -10dBm(0) to -25dBm(15)
1 = -15dBm(0) to -30dBm(15)
2 = -20dBm(0) to -35dBm(15)
3 = -25dBm(0) to -40dBm(15)
4 = -30dBm(0) to -45dBm(15)
5 = -35dBm(0) to -50dBm(15)
6 = -40dBm(0) to -55dBm(15)

Table of Contents