UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 683
Default
03
S/N Ratio
0~4 (0dB ~ -20dB)
04
No Tone Time
0~255 (30+30~7680ms)
(0 = not detect)
1~255 = 60~7680ms.
The formula is 30+30N.
When set to N=1, it means 30+30*1=60
When set to N=255, it means
30+30*255=7680
05
Pulse Count
1~255
06
ON Minimum Time
1~255 (30+30~7680ms)
07
ON Maximum Time
0~255 (30+30~7680ms)
08
OFF Minimum Time
1~255 (30+30~7680ms)
09
OFF Maximum Time
0~255 (30+30~7680ms)
12
Frequency No. 1
1~8 (Frequency Table No. set by 80-07)
13
Frequency No. 2 (OT)
0~8 (Frequency Table No. set by 80-07)
14
Twist Level (OT)
0-10 (1dB - 10dB)
Item No Item Input Data
Item Name Type 1 (DT) Type 2 (BT) Type 3 (RBT)
Type 4
(S-BT)
Type 5
(S-DT)
1
Detect Level
0 (-25dBm) 0 (-25dBm) 0 (-25dBm) 0 (-25dBm) 0
2
Min. detect
level
15 (-25dBm) 15 (-25dBm) 15 (-25dBm) 15 (-25dBm) 0
3
S/N ratio
4 (-20dB) 4 (-20dB) 4 (-20dB) 2 (-10dB) 0
4
No tone time
132 (3990ms) 132 (3990ms)
(OT)
13 (420ms) (AU)
132 (3990ms) 132 (3990ms) 0
5
Pulse Count
11 (OT)
2 (AU)
110
6
ON min. time
63 (1920ms)
(OT)
9 (300ms) (AU)
12(390ms) (OT)
10(330ms) (AU)
25 (780ms) 3 (120ms) 0
7
ON max. time
0 20(630ms) (OT)
14(450ms) (AU)
40
(1230ms)
13 (420ms) 0
8
OFF min.
time
1 (60ms) 12(390ms) (OT)
10(330ms) (AU)
52 (1590ms) (OT)
83(2520ms) (AU)
3 (120ms) 0