EasyManua.ls Logo

NEC Univerge SV8100 - Page 719

NEC Univerge SV8100
986 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 683
Default
03
S/N Ratio
0~4 (0dB ~ -20dB)
04
No Tone Time
0~255 (30+30~7680ms)
(0 = not detect)
1~255 = 60~7680ms.
The formula is 30+30N.
When set to N=1, it means 30+30*1=60
When set to N=255, it means
30+30*255=7680
05
Pulse Count
1~255
06
ON Minimum Time
1~255 (30+30~7680ms)
07
ON Maximum Time
0~255 (30+30~7680ms)
08
OFF Minimum Time
1~255 (30+30~7680ms)
09
OFF Maximum Time
0~255 (30+30~7680ms)
12
Frequency No. 1
1~8 (Frequency Table No. set by 80-07)
13
Frequency No. 2 (OT)
0~8 (Frequency Table No. set by 80-07)
14
Twist Level (OT)
0-10 (1dB - 10dB)
Item No Item Input Data
Item Name Type 1 (DT) Type 2 (BT) Type 3 (RBT)
Type 4
(S-BT)
Type 5
(S-DT)
1
Detect Level
0 (-25dBm) 0 (-25dBm) 0 (-25dBm) 0 (-25dBm) 0
2
Min. detect
level
15 (-25dBm) 15 (-25dBm) 15 (-25dBm) 15 (-25dBm) 0
3
S/N ratio
4 (-20dB) 4 (-20dB) 4 (-20dB) 2 (-10dB) 0
4
No tone time
132 (3990ms) 132 (3990ms)
(OT)
13 (420ms) (AU)
132 (3990ms) 132 (3990ms) 0
5
Pulse Count
11 (OT)
2 (AU)
110
6
ON min. time
63 (1920ms)
(OT)
9 (300ms) (AU)
12(390ms) (OT)
10(330ms) (AU)
25 (780ms) 3 (120ms) 0
7
ON max. time
0 20(630ms) (OT)
14(450ms) (AU)
40
(1230ms)
13 (420ms) 0
8
OFF min.
time
1 (60ms) 12(390ms) (OT)
10(330ms) (AU)
52 (1590ms) (OT)
83(2520ms) (AU)
3 (120ms) 0