Issue 10.1 UNIVERGE SV8100
2 - 300 Program 20 : System Option Setup
Description
(This program is aviable for V7000 or higher)
Use Program 20-45 : Remote Watch Setup to configure Remote Monitor settings.
Conditions
None
Feature Cross Reference
None
Program 20 : System Option Setup
20-45 : Remote Watch Setup
Level:
IN
Input Data
Terminal Number 1~6
Item
No.
Item Input Data Default
01
Ring Terminal for Remote Monitor
Extension Number (Up to 8
digits)
No Setting
02
Ring Time Setting
0000~2359
00:00
03
Ring Timer
0~60
0
04
Auto Dial Number Area Setting
0~1999
1999
05
VRS Answer for Message
0~100
0
06
VRS Message for Auto Dial
0~100
0
07
Time of Repeat Auto Dial
0~255
0
08
Auto Dial Calling Time
0~3600
0
09
Interval of Auto Dial
0~3600
0