Issue 10.1 UNIVERGE SV8100
2 - 100 Program 11 : System Numbering
Description
Use Program 11-06: ACI Extension Numbering to define the virtual extension number
to be used for the ACI. The extension number can have up to eight digits. The first
and second digits of the number should be assigned in Program 11-01 or Program 11-
20.
Default
ACI Port Numbers have no extension number set.
Conditions
None
Feature Cross Reference
Analog Communications Interface (ACI)
Flexible System Numbering
Program 11 : System Numbering
11-06 : ACI Extension Numbering
Level:
IN
Input Data
ACI Port Number 01~96
Item
No.
ACI Extension
Number
Description Related Program
01 Dial (Up to 8 digits) The extension number cannot
be duplicated in Programs 11-
02, 11-04, 11-07, 11-08, and
11-17.
10-03: Basic Configuration
for each blade.