UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 753
Description
Use Program 82-12: OPX Initial Data Setup to define the various initial data for OPX
packages.
Conditions
None
Feature Cross Reference
None
Program 82 : Basic Hardware Setup for Extension
82-12: OPX Initial Data Setup (AU)
Level:
IN
Input Data
Ite
m
No.
Item Description Input Default
01
Bounce Protect
Time
Specify a time for detection of
a valid off-Hook indication that
is long enough to prevent an
unintentional bounce of the
receiver from being detected
as a new Off-Hook indication
from a single line telephone.
0 = No Setting
1~15 = 100ms~1.5sec
3
(300ms)
02
HookFlash Start
Time
Specify the minimum
hookflash time from a single
line telephone or analog
Voice Mail system before it is
detected as the beginning of a
valid hookflash.
0 = 40ms
1~15 = 90ms~790ms
0 (40ms)
03
HookFlash End
Time
Specify the maximum
hookflash duration from a
single line telephone to
receive a second dial tone.
0 = HST+0ms
1~15=HST+100ms~HST+
1500ms (HST=Hookflash
Start Time)
1
(1600ms)