UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 275
Description
Use Program 20-18: Service Tone Timers to set the values for the system service
tone timers. Refer to the following chart for a description of each option, its range and
default setting.
Program 20 : System Option Setup
20-18 : Service Tone Timers
Level:
IN
Input Data
Item
No.
Item Input Data Default Description
Related
PRG
01
Extension Dial Tone
Time
0~64800s
30
After getting Intercom dial
tone, a telephone user has
this time to dial the first
digit of the Intercom call.
02
Busy Tone Timer
0~64800s
15
03
Congestion Tone
0~64800s
10
A Busy Tone when system
resources run short. (such
as DTMF receiver
resources).
04
Call Waiting Tone
Timer
0~64800s
10
This option sets the time
between Call Waiting
tones. This timer also sets
the time between Off-Hook
Signaling alerts.
05
Multiline Confirmation
Tone
0~64800s
10
06
Interval of Call
Waiting Tone
0~64800s (OT)
3~64800s (AU)
10
07
Intrusion Tone Repeat
Time
0~64800s
0
After a call is interrupted
(such as Barge-In, Voice
Mail Conversation
Recording, or Voice Over),
the system repeats the
Intrusion Tone after this
time. Normally, you should
enter 0 to disable this time.
08
Conference Tone
Interval
0~64800s
0
09
Warning Beep Tone
Signaling Interval
0~64800s
60 14-01-
18