NEC Univerge SV8100 - 41-03: Incoming Ring Group Assignment for ACD Group

NEC Univerge SV8100
986 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 485
Description
In Program 41-03: Incoming Ring Group Assignment for ACD Group, for each
incoming trunk group set up in Program 22-05, designate which ACD Group (1~64)
the trunks should ring for each of the eight Work Periods. Also use this program to
assign an Incoming Trunk Ring Group as priority or normal. Use Program 41-06 to set
up the Work Schedules and Work Periods for trunks. Use Program 41-07 to assign
the Work Schedules to the days of the week.
Conditions
None
Feature Cross Reference
Automatic Call Distribution (ACD)
Ring Groups
Program 41 : ACD Setup
41-03: Incoming Ring Group Assignment for ACD Group
Level:
SA
Input Data
Incoming Ring Group Number 1~100
ACD Work Period Mode Number 1~8
Item
No.
Item Input Data Default
01
ACD Group Number
0~64 (0 = No setting)
0
02
Night Announcement Service
0 = No
1 = Yes
0
03 Priority Data
Determine whether an incoming call to a trunk ring
group should follow a priority assignment.
0 = No Priority
1~7: 1 = Highest Priority
7 = Lowest Priority
0, 1~7
(0 = No Priority)
(1 = Highest Priority)
(7 = Lowest Priority)
0