UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 705
Description
Use Program 81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup to define the
various basic timers for layer 3 of ISDN BRI/PRI (defined in Program 10-03-04).
Program 81 : Basic Hardware Setup for Trunk
81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup
Level:
IN
Input Data
Layer 3 Timer Type Number 1~5
Item
No.
Item Description Input Data Default
01
T301 Specifies the timer value in 1/100ths
of a second of the timer to be started
when the ALERT message is
received.
0,180~254 (sec)
180 (sec)
02
T302 Specifies the timer value in 1/100ths
of a second of the timer to be started
when the SETUP ACK is sent. Timer
is also restarted when INFO is
received.
1~254 (sec)
15 (sec)
03
T303 Specifies the timer value in 1/100ths
of a second of the timer to be started
when SETUP is sent.
1~254 (sec)
4 (sec)
04
T304 Specifies the timer value in 1/100ths
of a second of the timer to be started
when the SETUP ACK is received.
Timer is also restarted when INFO is
received.
0~254 (sec).
30 (sec)
05
T305 Specifies the timer value in 1/100ths
of a second of the timer to be started
when DISC without progress No. 8 is
sent.
1~254 (sec)
30 (sec)
06
T306 Specifies the timer value in 1/100ths
of a second of the timer to be started
when DISC with progress indicator
No. 8 is sent. This timer is valid for
Network side use only.
0~254 (sec)
30 (sec)
07
T307 Specifies the timer value in 1/100ths
of a second of the timer to be started
when SUSPEND ACK is sent. This
timer is valid only for Network side
use only.
1~254 (sec)
180 (sec)

Table of Contents