Issue 10.1 UNIVERGE SV8100
2 - 706 Program 81 : Basic Hardware Setup for Trunk
08
T308 Specifies the timer value in 1/100ths
of a second of the timer to be started
when REL is sent.
1~254 (sec)
4 (sec)
09
T309 Specifies the timer value in 1/100ths
of a second upon data link
disconnection.
1-254 (sec)
90 (sec)
10
T310 Specifies the timer value in 1/100ths
of a second of the timer to be started
when CALL PROC is sent.
0~180 (sec)
180 (sec)
11
T312 Specifies the timer value in 1/100ths
of a second of the timer to be started
when SETUP is sent or re-sent on
broadcast data link. This timer is only
valid for Network side use only.
1~254 (sec)
6 (sec)
12
T313 Specifies the timer value in 1/100ths
of a second of the timer to be started
when connection request is sent.
Valid range 1 ~ 4 seconds in 1 second
increments. Value of 0 indicates timer
not used.
1~254 (sec)
4 (sec)
13
T314 Specifies the timer value in 1/100ths
of a second of the timer to be started
when message segment is received.
1~254 (sec)
4 (sec)
14
T316 Specifies the timer value in 1/100ths
of a second of the timer to be started
when RESTART is sent.
(T317+1)~254 (sec)
120 (sec)
15
T317 Specifies the timer value in 1/100ths
of a second of the timer to be started
when RESTART is received.
1~(T316-1)
60 (sec)
16
T318 Specifies the timer value in 1/100ths
of a second of the timer to be started
when RES is sent. This timer is valid
for user side use only.
1~254 (sec)
4 (sec)
17
T319 Specifies the timer value in 1/100ths
of a second of the timer to be started
when SUSPEND is sent. This timer is
valid for user side use only.
1~254 (sec)
4 (sec)
18
T320 Specifies the timer value in 1/100ths
of a second when B-channel access:
connection is received, or D-channel
access: DL-ESTABLISH confirmation
or indication is received.
1~254 (sec)
30 (sec)
19
T321 Specifies the timer value in 1/100ths
of a second of the timer to be started
when STATUS ENQ is received.
1~254 (sec)
30 (sec)
20
T322 Specifies the timer value in 1/100ths
of a second upon D-channel failure.
1~254 (sec)
4 (sec)
Item