2 - 280 Program 20 : System Option Setup
Description
Use Program 20-21 : System Options for Long Conversation to define the system
options for the Long Conversation feature.
Conditions
None
Feature Cross Reference
Long Conversation Cutoff
Program 20 : System Option Setup
20-21 : System Options for Long Conversation
Level:
IN
Input Data
Item
No.
Item Input Data Default
Related
Program
01
Long Conversation Alarm 1
The warning tone for long toll calls sounds after
this time.
0~64800 (sec)
170 14-01-15
02
Long Conversation Alarm 2
After the initial long toll call warning tone,
additional warning tones sound after this time.
0~64800 (sec)
180 14-01-15
03
Long Conversation Cutoff for Incoming Call
This timer determines how long the system
waits before disconnecting an incoming call.
0~64800 (sec)
0 14-01-14
04
Long Conversation Cutoff for Outgoing Call
This timer determines how long the system
waits before disconnecting an outgoing call.
0~64800 (sec)
0 14-01-14
05
Conversation Cutoff for Remote Monitor
0~64800 (sec)
108