UNIVERGE SV8100 Issue 10.1
Programming Manual 3 - 945
Description
Use Program 93-03 : Extension Information to display the settings of each
extension.
Program 93: System Information
93-03 : Extension Information
Level:
IN
Input Data
Extension Number Up to 8 digits
Item
No.
Item Input Data Default
Related
Program
01
Call Forward - All/No
Answer/Both Ring
Read only.
Indicates Call Forward -
All/No Answer/Both Ring
setting status per
extension.
0: = Call Forwarding off
1 = Call Forwarding with
Both Ringing
2 = Call Forwarding when
No Answer
3 = Call Forwarding All
Call
None 11-11-01
11-11-03
11-11-04
11-11-05
02
Call Forwarding
Destination for Both
Ring, All Call, No Answer
Read only.
Indicates Call Forward-All/
No Answer/BothRing
destination number set per
extension.
0-9, *, #, P, R,@
(Up to 24 digits)
None 11-11-01
11-11-03
11-11-04
11-11-05
03
Call Forward-Busy
Read only.
Indicates Call Forward-
Busy setting status per
extension.
0:Call Forward-Off
1:Call Forward-Busy or No
Answer
2:Call Forward-Busy
None 11-11-02
11-11-04
04
Call Forwarding Busy
Destination.
Read only.
Indicates Call Forward-
Busy destination number
set per extension.
0-9, *, #, P, R,@
(Up to 24 digits)
None 11-11-02
11-11-04

Table of Contents