Description
Use Program 20-22 : System Options for Wireless – DECT Service to define the
time the system waits before determining the Wireless – DECT phone is out of range.
For incoming calls, the timer begins when the call is received. If the time defined here
expires before the Wireless – DECT phone starts to ring, the system determines the
phone is out of range and provides the out-of-range services (indicates out-of range,
transfers the call to voice mail or to another extension).
Conditions
None
Feature Cross Reference
Wireless – DECT
Program 20 : System Option Setup
20-22 : System Options for Wireless – DECT Service
Level:
IN
Input Data
Item
No.
Item Input Data Default
05
Out of area judging time (AU)
0~64800s
8
06
Out of Area Talkie Number
0~100
0