Issue 10.1 UNIVERGE SV8100
2 - 158 Program 14 : Trunk, Basic Setup
Conditions
None
Feature Cross Reference
None
13
Trunk-to-Trunk Limitation
0 = Disable (No)
1 = Enable (Yes)
0
14
Loop Start/Ground Start
0 = Loop Start (Loop)
1 = Ground Start
(Ground)
0
16
Caller ID Type
0=FSK
1=DTMF
0
17
Sync. Ringing
Use this to specify whether or not CO/
PBX calls follow Synchronous Ringing.
Synchronous Ringing does not
apply to incoming DID calls,
off-hook ringing calls, or CO/
PBX ring transfer calls.
0 = Disable
1=Enable
0 (OT)
1 (AU)
18
Busy Tone Detection on Talking
0 = Disable
1=Enable
0
19
Busy Tone Detection Frequency
1~255
1 14-02-18
20
Busy Tone Detection Interval
0 = No
1 = Yes
0 14-10
21
Fax Branch Connection
0 = No
1 = Yes
0 14-10
22
Deny Collect Call Receiving for CO
Trunk (OT)
0 = Disable
1=Enable
0
23
Caller ID Receiving Method (AU)
Rings extension before receiving
Caller ID (1) or after receiving Caller ID
(0).
0: Wait Caller ID
1: Immediate Ring
1
Item
No.
Item Input Data Default
Related
Program

Table of Contents

Other manuals for NEC Univerge SV8100