UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 195
47
Registration
Expire Timer
for NAPT
0 = Disable
60 ~ 65535(sec)
180
On a per station
basis, this setting
defines the SIP
registration expiry
timer. This setting
only applies to
DT700 stations or
Standard SIP
Terminal
connected via
NAPT. If this value
is set to 0, for a
NAPT terminal,
the value in PRG
84-23- 01 (for
DT700) or
PRG10-33-01 (for
Standard SIP
Terminal) are
applied.
With Version 9.5
or higher
software, when
the SIP Terminal
client connects
via NAPT, this
timer is necessary
to adjust this
confirming with
each Internet
carrier setting.
10-46-14
48
Subscribe
Expire Timer
for NAPT
0 = Disable
60 ~ 65535(sec)
180
On a per station
basis, this setting
defines the SIP
Subscribe expiry
timer. This setting
only applies to
DT700 stations
connected via
NAPT. If this value
is set to 0, for a
NAPT terminal,
the value in PRG
84-23-02 is
applied.
Note: Version 9.0
or higher is
required.
10-46-14
Item
No.
Item Input Data Default Description