Issue 10.1 UNIVERGE SV8100
2 - 238 Program 20 : System Option Setup
Conditions
None
Feature Cross Reference
Refer to the Input Data table at the beginning of this section.
09
Callback/Trunk
Queuing Cancel
Time
0~64800s
64800s
The system cancels an
extension Callback or
Trunk Queueing request
after this time.
11-12-05
15-07-35
10
Trunk Guard
Timer
0~64800s
1
The amount of time the
system waits to seize the
next outside line after the
system releases an
outside line.
12
Telephone/Web
Pro Logout Time
1~84600s
(84600s =1
day)
900s
(15min)
The system automatically
logs out of a Telephone/
Web Pro session after
inactivity lasting this time.
14
Special
Character Input
Mode
0 = Latin
1 = Cyrillic
2 = Simplified
Chinese
3 = Traditional
Chinese
2
Only when 2 or 3 is
selected you can use PC
Pro or WebPro to use
Chinese Characters.
Please note Chinese
Character can not be
enter through Telephone
Pro.
16
Mobile
Extension
Callback
Duration Time
1~64800(sec)
15
Set up the system
callback duration time
when ringing the target
Mobile Extension.
15-22-04
19
Emergency call
setting of remote
inspection
feature when the
target is in off-
hook status
0 = Off
1 = On
0
Setting to On (1) allows
an emergency call to be
made when the
inspection target is in off-
hook status.
20
Progress Tone
for Mobile
Extension
Setting
0 = Disable
1 = Enable
1
Setting on where the
Progress Tone (1) or
Ringback (0) is played to
the Internal Caller until
the call to the Mobile
Extension is setup.
80-01
(Type 54)
Input Data
Item
No.
Item Input Data Default Description
Related
Program