Issue 10.1 UNIVERGE SV8100
2 - 6 Program 10 : System Configuration Setup
02
Logical Port Number
(B1)
0=Not set
1 = Multiline Terminal (1~512)
2 = SLT Adapter (OT) (1~512)
3 = BCH (Bluetooth Cordless Handset)
(1~512)
6=
PGD Adapter (Paging) (1~8)
7=
PGD Adapter (for Tone Ringer)
(1~8)
8=
PGD Adapter (for Door Box) (1~8)
9=
PGD Adapter (for ACI) (1~96)
10 = DSS (1~32)
0
03
Additional Data
0=None
3 = Bluetooth Cordless Handset: 01-16
0
04
Optional Installed Unit 1
(Only applies to Aspire
style telephones)
0=None
1=APR Module
2 = APA Module
3 = ADA Module
4 = CTA/CTU Module
0
05
Optional Installed Unit 2
0=None
1=APR Module
2 = APA Module
3 = ADA Module
4 = CTA/CTU Module
0
B-Channel 2
Item
No.
Item Input Data Default
06
Terminal Type (B2)
0 = Not set
6 = PGD Adapter (Paging)
7 = PGD Adapter (Tone Ringer)
8 = PGD Adapter (Door Box)
9 = PGD Adapter (ACI)
12 = APR (B2 Mode)
0
07
Logical Port Number (B2)
0 = Not set
6 = PGD Adapter (Ext. Speaker)
7 = PGD Adapter (Paging/Tone Ringer) =
(1~8)
8 = PGD Adapter (for Door Box) = (1~8)
9 = PGD Adapter (ACI) = (1~96)
12 = APR (for B2 mode) (193~512)
0
Item
No.
Item Input Data Default