Issue 10.1 UNIVERGE SV8100
2 - 720 Program 81 : Basic Hardware Setup for Trunk
05
Incoming Signal Detect Time Selection
Specify the time after the incoming signal
from another system is detected before the
acknowledge signal is sent out.
Wink Start
1~15
(130ms~1950ms)
(0 = No Setting)
Delay
1~15
(30ms~450ms)
(0 = No Setting)
Wink Start
3
(390
Delay
3
(90)
06
Loop Off-Guard Time Selection
Assign loop off-guard time to prevent noise
that could cause the system to be unable to
answer an incoming Tie line.
1~4
(0.5sec~2.0sec)
5~15
(3sec~13sec)
(0 = No Setting)
4
(2.0)
07
Length of Wink Signal Selection
Specify the time a wink pulse is sent to
another system.
0~15
(30ms~480ms)
5
(180)
08
Length of Delay Signal Selection
Specify the time a delay pulse is sent to
another system.
1~15
(300ms~4.5sec)
(0 = No Setting)
1
(300ms)
09
Incoming Interdigit Timeout Selection
Specify the time that an address signal is
missing during the incoming call detection
process before an error tone is returned to
the other system.
0 = 8
1~15
(1~15 seconds)
6
10
Wink/Delay Signal Detect Timeout
Selection
To specify a maximum time, in seconds, for
receiving an acknowledgment signal from a
distant system before sending a busy tone.
0 = 8
1~15
(1~15 seconds)
7
11
Disconnect Recognition Time Selection
Specify the minimum time before a
disconnected circuit can be accessed
again.
1~15
(0.1~1.5 seconds)
(0 = No Setting)
3
(0.3)
12
Automatic Release Signal Detection
Selection
Specify the signal detection time for release
of a Tie Line after a disconnect signal is
received from the distant CO or PBX.
1~14
(50~700ms)
15 =
(No limit)
(0 = No Setting)
7
(350)
13
Pause Time Selection
1~15
(500~7500ms)
6
(3000ms)
Item
No.
Item Input Data Default