M3SR Series 4100 Changing the PEP (Peak Envelope Power) to Average Power Factor
3.164 Operating Manual 6175.4760.02 01
3.7.2.27 Changing the PEP (Peak Envelope Power) to Average Power Factor
Softkey Softkey Type Description
Editor 1. Press 'PEP/PAvg' softkey.
2. Change to desired value.
Possible values:
0 dB to 12 dB
With this setting, the automatic level control
(ALC) of the power amplifier can be adjusted
to the characteristic of external modems to
achieve highly linear signal amplification. It af-
fects the J2D and B7D Tx direction only.