M3SR Series 4100 Deleting the LQA Table
4.94 Operating Manual 6175.4760.02 – 01
4.4.5.5 Deleting the LQA Table
Softkey Selection / Editor Description
Activate 1. Press 'DEL LQA TABLE' softkey.
When the position of a radio was completely
changed or when the antenna was exchanged
(log periodic beam antenna instead of whip), it
might be reasonable to delete the LQA table to
avoid wrong decisions of the best channel al-
gorithm, which is based on this table.
This accelerates the adaptation to the new
propagation conditions.
During normal operation, it is not recommend-
ed to delete the LQA table, it would make the
next link setup less reliable.
See
sect. 4.4.4.4 Selecting the Call Channel Type
, where the ‘best channel’ can be selected au-
tomatically.