Operating Manual 6175.4760.02 – 01 4.53
M3SR Series 4100 Switching Protected Coarse Time Request (Time Lag < 1 min) On or Off
4.3.6.17 Switching Protected Coarse Time Request (Time Lag < 1 min) On or Off
Softkey Selection / Editor Description
Toggle
In the central area the currently active value is
displayed.
1. Press softkey to toggle coarse time syn-
chronization on/off.
The new value is selected immediately.
Possible values:
•ON
•OFF
With the protected coarse time request, the
time lag between the two stations is allowed to
be as great as one minute. Here time trans-
mission also is protected.