EasyManua.ls Logo

R&S M3SR 4100 Series - 6 Malfunction; Visual Inspection

R&S M3SR 4100 Series
706 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Manual 6175.4760.02 01 6.1
M3SR Series 4100 Malfunction
6 Malfunction
6.1 Visual Inspection
If a connector shows any discoloration caused by heat, its mating connector is also
defective and must also be replaced.
Check the following:
1. Check the external wiring between the radio with or without the control unit and the ex-
ternal equipment.
2. Check if all connectors are plugged in firmly.
3. Check the power supply cable and the RF coaxial cables at the rear for mechanical dam-
age.
4. Check fuses at the rear and replace (see sect. 6.1.1 Fuses F1 / F2 - Change), if defec-
tive.
If necessary, replace cables by new ones one by one until the defective connection has been
found.
Obvious damage of minor importance can be corrected at once, assuming that the appropri-
ate equipment is available. In case of severe damage, the transceiver must be sent to the
nearest repair facility.