EasyManua.ls Logo

R&S M3SR 4100 Series - SECOM-H Configuration Menus

R&S M3SR 4100 Series
706 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M3SR Series 4100 SECOM-H Configuration Menus
4.180 Operating Manual 6175.4760.02 01
4.8.4 SECOM-H Configuration Menus
In the central area of the configuration menu 1/2 the currently set configuration parameters
are displayed.
Figure 4.40 Menu 1321: SECOMH CFG 1/2
1 Current Time Source, SECOM-H Time and Date
2 Current Selected Vocoder Type
3 Current Number of Channels in an Advanced Hopset
The configuration menu 1/2 offers various configuration possibilities.
In the central area of the configuration menu 2/2 you can select the User Hopset and User
Keyset folders. SECOM-H CFG 2/2 is a special editor to select/modify and delete user
hopsets and user keysets.
1
2
3
ICN-4D-G-231021-R-D0894-00009-A-01-1

Table of Contents