RM0091 Universal synchronous asynchronous receiver transmitter (USART)
Doc ID 018940 Rev 1 581/742
When a character is received
The RXNE bit is set. It indicates that the content of the shift register is transferred to the
RDR. In other words, data has been received and can be read (as well as its
associated error flags).
An interrupt is generated if the RXNEIE bit is set.
The error flags can be set if a frame error, noise or an overrun error has been detected
during reception. PE flag can also be set with RXNE.
In multibuffer, RXNE is set after every byte received and is cleared by the DMA read of
the Receive Data Register.
In single buffer mode, clearing the RXNE bit is performed by a software read to the
USART_RDR register. The RXNE flag can also be cleared by writing 1 to the RXFRQ
in the USART_RQR register. The RXNE bit must be cleared before the end of the
reception of the next character to avoid an overrun error.
Break character
When a break character is received, the USART handles it as a framing error.
Idle character
When an idle frame is detected, there is the same procedure as for a received data
character plus an interrupt if the IDLEIE bit is set.
Overrun error
An overrun error occurs when a character is received when RXNE has not been reset. Data
can not be transferred from the shift register to the RDR register until the RXNE bit is
cleared.
The RXNE flag is set after every byte received. An overrun error occurs if RXNE flag is set
when the next data is received or the previous DMA request has not been serviced. When
an overrun error occurs:
The ORE bit is set.
The RDR content will not be lost. The previous data is available when a read to
USART_RDR is performed.
The shift register will be overwritten. After that point, any data received during overrun
is lost.
An interrupt is generated if either the RXNEIE bit is set or EIE bit is set.
The ORE bit is reset by setting the ORECF bit in the ICR register.
Note: The ORE bit, when set, indicates that at least 1 data has been lost. There are two
possibilities:
if RXNE=1, then the last valid data is stored in the receive register RDR and can be
read,
if RXNE=0, then it means that the last valid data has already been read and thus there
is nothing to be read in the RDR. This case can occur when the last valid data is read in
the RDR at the same time as the new (and lost) data is received.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STMicroelectronics STM32F05 series and is the answer not in the manual?

STMicroelectronics STM32F05 series Specifications

General IconGeneral
BrandSTMicroelectronics
ModelSTM32F05 series
CategoryMicrocontrollers
LanguageEnglish

Related product manuals