ERROR CODE and TROUBLESHOOTING
8 - 317
8.5.15 Color banding (in feeding direction)
Fig.8-23
Cause/Section Step Check item Measures
Laser optical
unit, Main
charger grid
1 Perform the enforced performing of
image quality closed-loop control (05-
2742).
When the enforced performing of
image quality closed-loop control is
performed, the automatic cleaning of
main charger and the LSU slit glass
cleaning are performed at the same
time.
Scanner 2 Is there foreign matter in the optical
path?
Clean the slit, lens and mirrors.
3 Is there dust or stain on the shading
correction plate or ADF original
glass?
Clean it.
Main charger 4 Is there foreign matter on the charger
grid?
Remove foreign matter.
5 Is the charger grid dirty or deformed? Clean or replace the charger grid.
6 Is there foreign matter on the main
charger?
Remove foreign matter.
7 Is the needle electrode dirty or
deformed?
Clean or replace the needle
electrode.
8 Is the needle electrode cleaner dirty
or deformed?
Clean or replace the needle electrode
cleaner.
9 Is the inner surface of charger case
dirty?
Clean inside.
Drum cleaner 10 Is there any foreign matter on the
drum cleaning blade edge?
Clean or replace the drum cleaning
blade.
11 Is toner recovery defective? Clean the toner recovery auger
section.