4.6.27 Doctor blade
4.6.28 Auto-toner sensor-K/C/M/Y (S26/S27/S28/S29)
(8) Take off the developer sleeve.
Notes:
When installing, adjust the gap between the
developer sleeve and the doctor blade.
Fig. 4-340
(1) Take off the blade cover.
P. 4-114"4.6.26 Developer sleeve"
(2) Remove 2 screws and then take off the
doctor blade.
Fig. 4-341
(1) Take off the corresponding process unit
(EPU) in which the auto-toner sensor is
installed, and then take off the developer unit
to remove the developer material out of the
unit.
P. 4-110"4.6.24 Developer unit"
P. 4-112"4.6.25 Developer material"
(2) Disconnect 1 connector, remove 1 screw,
and then take off the auto-toner sensor.
Fig. 4-342