EasyManua.ls Logo

Toshiba e-STUDIO 6550Ce-STUDIO 5560C - Tandem LCF Tray-Up Motor

Toshiba e-STUDIO 6550Ce-STUDIO 5560C
1499 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
DISASSEMBLY and REPLACEMENT
4 - 79
4.5.49 Tandem LCF tray-up motor (M46)
(4) Release 3 latches and then take off the
transfer belt paper clinging detection sensor.
Fig. 4-230
(1) Pull out the tandem LCF.
(2) Take off the FIL board case and reactor.
P. 9-21"9.1.18 FIL board"
(3) Take off the switching regulator.
P. 9-18"9.1.15 Switching regulator (PS)"
(4) Take off the PFC board case.
P. 9-8"9.1.9 PFC board case"
(5) Disconnect 1 connector and remove 3
screws. Then take off the tandem LCF tray-
up motor unit.
Fig. 4-231
(6) Release 2 latches and then take off the
coupling [1] and spring [2].
Fig. 4-232
Transfer belt paper clinging detection sensor
Tandem LCF tray-up motor unit
[
1
]
[
2
]

Table of Contents