4
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
DISASSEMBLY and REPLACEMENT
4 - 165
4.8 Image Quality Control
4.8.1 Image quality control unit
4.8.2 Image position aligning sensor (front) (S20)
4.8.3 Image position aligning sensor (center) (S21)
(1) Take off the transfer cam unit.
P. 4-163"4.7.25 2nd transfer roller
contact/release detection sensor (S50)"
(2) Remove 2 shoulder screws and then take off
the image quality control unit.
Fig. 4-483
(1) Take off the image quality control unit
P. 4-165"4.8.1 Image quality control unit"
(2) Remove 2 screws and take off the image
position aligning sensor (front).
Fig. 4-484
(1) Take off the image quality control unit
P. 4-165"4.8.1 Image quality control unit"
(2) Remove 2 screws and take off the image
position aligning sensor (center).
Fig. 4-485
Shoulder screw
Image quality control unit
Image position aligning sensor (front)
Image position aligning sensor (center)