e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C © 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
SELF-DIAGNOSTIC MODE
5 - 62
<Value>1</Value>
</Code>
</Category-08>
<Category-13/>
</Data>
</Policy>
Notes:
• The setting value of the code in step 10 is written by inserting a comma to divide the values.
E.g.: 08-4106 <Value>128,128</Value>
• Setting is carried out in order of written.
• The read-only codes and the execution codes are skipped to continue the processing if they
are included.
• If writing of the setting value has failed, the processing will stop at that moment and then an
error message will appear in the screen.
5.16.4 Result files
[ 1 ] Result files
A file in which success or failure of the replacement of the setting values for each code included in the
setting files is written. A result file is stored in a USB storage device after this code is performed.
File name: DIG_ RESULT_XXXX_yymmddhhmmss.xml (XXXX: Serial No.)
File format: xml format
[ 2 ] Example
<Policy>
<Data>
<Category-05/>
<Category-08>
<Code>
<MainCode>3807</MainCode>
<RESULT>SUCCESS</RESULT>
</Code>
<Code>
<MainCode>9240</MainCode>
<RESULT>FAILED</RESULT>
</Code>
<Code>
<MainCode>9264</MainCode>
<SubCode>1</SubCode>
<RESULT>UNSPECIFIED</RESULT>
</Code>
</Category-08>
<Category-13/>
</Data>
</Policy>
* SUCCESS Values are updated successfully.
* FAILED Update of values fails.
* UNSPECIFIED No codes written exist.
A value to be set is outside the assignable range.
Notes:
• A result file is stored in the root folder of a USB storage device.
• As for the codes whose values have been altered caused by batch setting of another one,
their items, such as the code number, value changed and success/failure of the change, are
not described in a result file.
• If writing of the setting value has failed, the processing will stop at that moment. Only the
codes whose writing has succeeded will be described in a result file.