7
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
PREVENTIVE MAINTENANCE (PM)
7 - 75
7.10 Maintenance Part List
The parts used for the maintenance of this equipment are as follows.
*1: Part list <P-I> represents the page item in “e-STUDIO5540C/6540C/6550C, e-STUDIO5560C/
6560C/6570C Service Parts List”.
No. Item Purpose
Parts list
<P-I>
*1
1 Cleaning brush Cleaning inside of the equipment 201-1
2 Doctor blade cleaning jig Cleaning the doctor blade 201-7
3 Wire holder jig Fixing the wire at the assembly of the carriage wire 201-2
4 RADF positioning pin Determining the position of the RADF 201-5
5 Doctor-sleeve jig Measuring the gap between the development sleeve
and the doctor blade
201-6
6 Belt tension jig Adjusting the belt tension at the installation of the
scan motor
201-3
7 Separation plate gap jig Measuring the gap between the separation plate and
the fuser belt
201-11
8 Thermostat gap confirmation jig Measuring the gap between the thermostat and the
fuser belt, and the thermostat and the pressure roller
201-9
9 Thermistor gap confirmation jig Measuring the gap between the thermistor and the
pressure roller
201-10
10 Drum bag Storing the drum 201-4
11 Download jig (DLM board) Updating the scanner/options ROM 202-1
12 ROM Installing the DLM board 202-10
13 Download jig-2 (6 Flash ROMs) Updating the system/engine ROM 202-2
14 ROM writer adapter (For 1881) Writing the data of PWA-DWNLD-350-JIG2 202-4
15 ROM writer adapter (For 1931) Writing the data of PWA-DWNLD-350-JIG2 202-5
16 Toner seal plate*2 Preventing foreign matter from entering into the toner
supply opening (for transporting the unpacked
equipment)
201-8
17 Patting powder For transfer belt 201-12
18 Color test chart (TCC-2) For test print (A4/LT) 201-13
19 Color test chart For test print (A3/LD) 201-25