e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C © 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
DISASSEMBLY and REPLACEMENT
4 - 252
4.10.50 Duplexing unit cover opening/closing detection switch (SW7)
Notes:
When the duplexing unit cover opening/closing detection sensor is replaced or removed, be sure
to perform the operation check with the output check (test mode 03). If the installation is
insufficient, this sensor is not performing properly. In this case, you may touch the rotating
portions in the drive motor during the drive and could be injured as a result.
(5) Take off the duplexing unit path entrance
sensor from the sensor bracket.
Fig. 4-734
(1) Take off the duplexing unit upper cover.
P. 4-241"4.10.37 Duplexing unit upper
cover"
(2) Remove 2 screws and then take off the
duplexing unit cover opening/closing
detection sensor.
(3) Release a clamp, and then disconnect 2
connectors from the duplexing unit cover
opening/closing detection sensor.
Fig. 4-735
Duplexing unit path entrance sensor
Duplexing unit cover
opening/closing detection sensor