DISASSEMBLY and REPLACEMENT
4 - 43
4.4.7 Shutter sensor (end position)
4.4.8 Disassembly and replacement of the Polygonal motor
Notes:
Polygonal motor replacement is not recommended in the field; the image quality is not
guaranteed in such a case.
(1) Remove the laser optical unit.
P. 4-35"4.4.1 Laser optical unit"
(2) Remove the shutter.
P. 4-41"4.4.4 Shutter"
(3) Disconnect 1 connector.
Fig. 4-121
(4) Release 2 latches and take off the shutter
sensor (end position).
Fig. 4-122
(1) Take off the laser optical unit. (Refer to
SERVICE MANUAL P. 4-35"4.4.1 Laser
optical unit")
Latch
Shutter sensor
(end position)