e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C © 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
SETTING ADJUSTMENT
6 - 82
6.6.2 Belt tension adjustment of the Scan motor
(1) Hook the belt tension jig to the motor bracket
and the flame.
(2) Loosen screw-A and -C. (There is no need to
loosen screw-B, since it is a shoulder screw.)
(3) The scan motor is pulled by the belt tension
jig. Fix screw-A and then -C at the stopped
position.
(4) Remove the belt tension jig.
Fig.6-28
Fig.6-29
C
A
B
Pully
Timing belt
Scan motor
Belt tension jig