e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C © 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
SETTING ADJUSTMENT
6 - 92
6.8 Process Unit Related Section
6.8.1 High-Voltage Transformer Setting
The high-voltage transformers supply high-voltage to the parts related to charging, development,
transfer and Discharging blade.
The high-voltage transformer has the following high-voltage outputs.
Notes:
Never move the variable resistance on the board since the output adjustment has been
performed at the shipment for the high-voltage transformer supplied as a service part. Also do
not perform the setting change when the high-voltage power supply is replaced.
6.8.2 Adjustment of the Auto-Toner Sensor
When the developer material is replaced, adjust the auto-toner sensor in the following procedure.
P. 6-2"6.1.2 Adjustment of the Auto-Toner Sensor"
Out1 1 Main charger needle electrode cleaner bias (Y)
2 Main charger needle electrode cleaner bias (M)
3 Main charger needle electrode cleaner bias (C)
4 Main charger needle electrode cleaner bias (K)
Out2 1 Main charger grid bias (Y)
2 Main charger grid bias (M)
3 Main charger grid bias (C)
4 Main charger grid bias (K)
Out3 1 Developer bias (Y)
2 Developer bias (M)
3 Developer bias (C)
4 Developer bias (K)
Out4 1 1st transfer roller bias (Y)
2 1st transfer roller bias (M)
3 1st transfer roller bias (C)
4 1st transfer roller bias (K)
Out5 - 2nd transfer roller bias